Automatic Digital Upper Arm Blood Pressure Pulse Check Blood Monitor
Automatic Digital Upper Arm Blood Pressure Pulse Check Blood Monitor

Automatic Digital Upper Arm Blood Pressure Pulse Check Blood Monitor

(0)
Item code #:5D923

stock more than 100

You're eligible for PayPal's 180-day
Buyer Protection

No-Fuss 14 Day Return
Free Return

£ 18

QTY:

Summary

 

The blood pressure monitor can store 99 groups of memory. After each measurement, the blood pressure monitor will automatically store measured data. When the memory capacity is full, old measured data will be covered by new data.

Measurement range: Pressure:20-280 blood pressure:(2.7-37kPa) Pulse:40-160times/min

DegC~40 DegC(do not include 15 DegC~25 DegC) within ±6 blood pressure(±0.8kPa) Pulse: within ±5%

Automatic Digital Upper Arm Blood Pressure Pulse Check Blood Monitor Description

NOTE: Need to Press ON/OFF Button Twice To Start Measuring After Put The Batteries On or Connect The Device To Power By USB Line

 

The blood pressure monitor can store 99 groups of memory. After each measurement, the blood pressure monitor will automatically store measured data. When the memory capacity is full, old measured data will be covered by new data.

 

Specification:

 

Size of Cuff: 22-32cm(8.65-12.59 inch)

 

1.Power supply: DC6V four AAA batteries (not included)/AC Stabillized-voltage

 

2.Display: Digital liquid crystal display

 

3.Measurement mode: Oscillometric method

 

4.Measurement range: Pressure:20-280 blood pressure:(2.7-37kPa) Pulse:40-160times/min

 

5.Accuracy: 15°C~25°C within ±3 blood pressure(+/- 0.4kPa)

 

5 DegC~40 DegC(do not include 15 DegC~25 DegC) within ±6 blood pressure(±0.8kPa) Pulse: within ±5%

 

6.Normal working environment: Temperature 5°C~40 DegC Moisture:=85%

 

7.Store&transport environment: Temperature 20°C~55 DegC Moisture:10%~93%

 

8.Operating air pressure: 85kPa~105kPa

 

9.Operate&store air pressure: 50kPa~105kPa

 

10.Quick exhaust way: Electronic discharge valve

 

11.Overpressure protection: over 295 blood pressure(20MS), discharge automatically

 

12.Auto power off: Auto power off when no operation for 1 minute

 

 

 

Blood Pressure Range:

 

Low Pressure 80 High Pressure 120: ideal blood pressure(target value)

 

Low Pressure 80-85 High Pressure 120-130: normal blood pressure

 

Low Pressure 85-90 High Pressure 130-140: normal value

 

Low Pressure 90-100 High Pressure 140-160: Mild hypertension

 

Low Pressure 100-110 High Pressure 160-180: Moderate hypertension

 

Lower High Pressure over 110 High Pressure over 180: Severe hypertension

 

 

 

Insert Batteries

 

1. turn over the instrument, press the triangle logo part of the battery cover, take out the battery cover along the arrow direction.

 

2. Confirm the + - charges of the battery and load the battery.

 

3. close the cover.

 

 

 

How to use AC stabilized-voltage battery?

 

1. plug AC stabilized-voltage power source to the correct socket.

 

2. plug AC power supply of DC stabilized-voltage power source to the correct insert of the instrument.

 

3. plug AC stabilized-voltage power source to the correct socket. )

 

How to use Bind Wrist Band

 

1. plug in the air tube - plug the air tube to the bottom

 

2. The volume tied to the arm cuff - roll and bind the wrist band on your bare arm. Export trachea should hand align the palm of the little finger. (It can be measured both right and left hand, but the results have different extent of difference. Please measure by the same side of arm each time)

 

3. roll wrist band tightly - don't roll in clothes or it affects the accuracy of measurement. don't roll too tight, can place one finger. (most appropiaterth) fasten the hasp.

 

How to use Measure Manual

 

1. Place elbow on the desk.

 

2. The wrist band and heart on the same level.

 

3. Palm and relax.

 

Measure at the same time with he same arm and same gesture each day.

 

position of the wrist band will cause the result to change.

 

you'd better measure your basic blood pressure, (pressure of wake up and do not want emiction in the morning) if you cannot, please take before marl or sports.

 

do not touch instrument, wrist band and air tube.

 

Be quiet and relaxed during measurement. Be quiet for at least 5 mins before measuring. Relax body, arm and fingers, no muscle activity. Do not speak during measuring, be quiet. Measure again 4 to 5 mins if you need to measure in succession.

 

Package:

 

Blood Pressure Monitor x 1 set

 

Product Tags

 

Upper Arm

0 / 5 based on 0 reviews.

Feedback for Automatic Digital Upper Arm Blood Pressure Pulse Check Blood Monitor